GE THQP120 Feeder Circuit Breaker, Type THQP, 20 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

Item Code: 6122311
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 cu or #12 to 8 al AWG wire, 30 to 50 A #8 to 4 cu or #8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Manufacturer GE
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 cu or #12 to 8 al AWG wire, 30 to 50 A #8 to 4 cu or #8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.

Specifications

UNSPSC Code

35.353.353

Weight

0.3lb

Height

3.65in

Width

4.25in

Length

10.75in

Actuator Type

Toggle

Current Rating

20 A

Dimensions

3.28 in L x 0.5 in W x 2.58 in H

Frame Type

Q-line

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Operating Frequency

50/60 Hz

Operating Temperature

60 to 75 deg C

Suitable For

Reverse Feed

Terminal Type

Lug

Trip Type

Non-Interchangeable

Type

Type THQP

Voltage Rating

120/240 V

Wire Size

14 to 8 12 to 8 AWG

Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 cu or #12 to 8 al AWG wire, 30 to 50 A #8 to 4 cu or #8 to 2 al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.

Specifications

UNSPSC Code

35.353.353

Weight

0.3lb

Height

3.65in

Width

4.25in

Length

10.75in

Actuator Type

Toggle

Current Rating

20 A

Dimensions

3.28 in L x 0.5 in W x 2.58 in H

Frame Type

Q-line

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Operating Frequency

50/60 Hz

Operating Temperature

60 to 75 deg C

Suitable For

Reverse Feed

Terminal Type

Lug

Trip Type

Non-Interchangeable

Type

Type THQP

Voltage Rating

120/240 V

Wire Size

14 to 8 12 to 8 AWG